Configure Medical-Objects Capricorn and Genie software to import electronic results (Version1.3)
Version 1.3
Overview:
Provide a procedure to install and configure Medical-Objects Capricorn and Genie Practice software to import electronic results.
This process is based on the Microsoft Windows environment.
Contents |
Types of installations
The first step in this process is determining what type of installation of Capricorn is installed. There are 2 options for this:
a) Service Installation (For Server Installations). The HL7 Tray Icon is not present. See Part 1.
b) Tray Icon Installation (For Workstation Installations).The HL7 Tray Icon is present as shown below. See Part 2.
Part 1: Service Installation
In the case of a Service Installation we will need to run the Tray Icon to access the Configuration Window. As mentioned previously we have 2 different types of installations, because of this we cannot run a service and a tray icon at the same time.
So in Part 1, we will stop the service and open the Tray Icon to access the configuration settings. Once the settings are configured we will close down the Tray Icon and restart the service.
1. Click the Start Menu and then Run
2. Type services.msc and click OK
3. The services window will be displayed
4. In the list locate CAPRICORN
5. Under Status, it should show as Started
6. Right click CAPRICORN and left click Stop from the Menu
7. The following window will display the progress
8. Now the Capricorn service has stopped
9. Start Capricorn form the Start Menu > All Programs > Medical-Objects > Medical Objects Capricorn or from the C:\MO\Capricorn\Capricorn.exe
10. The Tray Icon should now be visible in the system tray
11. Follow directions for Part 2: Tray Icon Installation
Important Note:
Now you can follow the steps in Part 2. Once changes have been made you will need to shutdown the Tray Icon and Restart the Service again.
Part 2: Tray Icon Installation
1. Double click the HL7 tray icon
Note: If the Capricorn HL7 tray icon is not visible, open Capricorn from the Start Menu > All Programs > Medical-Objects > Medical Objects Capricorn or from the C:\MO\Capricorn\Capricorn.exe
2. The Log window is displayed
3. Click the Edit Server Properties icon
4. The Login screen will appear as shown below
5. Enter the following Username and Password and then click OK
Username: SYSDBA
Password: masterkey
6. This will take you to the Configuration Editor window shown below
7. Once you have completed your configurations, Click OK to close the window
Configuring Capricorn Software
1. Click on the Integration Options
2. Set the ACK Management path as below:
(Capricorn installed on a Genie Server Machine) --> C:\Genie\Labrslts\Hl7 ACKS (Capricorn installed on a Genie Client Machine) --> \\server\Genie\Labrslts\Hl7 ACKS\
Note: If the folder does not exist you must create them.
3. Check that the Incoming Modifier is set to Genie REF
4. Select Server Parameters from the left panel
5. The paths above are set as follows:
(Capricorn installed on a Genie Server Machine) -->
i. Message Output Directory: C:\Genie\Labrslts\ ii. Save Pathology: C:\Genie\Labrslts\ iii. Save Radiology: C:\Genie\Labrslts\
(Capricorn installed on a Genie Client Machine) -->
i. Message Output Directory: \\server\Genie\Labrslts\ ii. Save Pathology: \\server\Genie\Labrslts\ iii. Save Radiology: \\server\Genie\Labrslts\
- Make Sure that “Save all ORU in Pathology Path” is UNTICKED
6. The Medical-Objects configuration is complete. Click Apply and OK
Note: Remember if you had a Service Installation you will need to close the Tray Icon and restart the Service.
Should you require any more information or have encountered a problem please call the support helpdesk on (07) 5456 6000.