Configuring Medical-Objects Capricorn and "The Practice" to import electronic results
Overview
Provide a procedure to install and configure Medical-Objects Capricorn and "The Practice" software to import electronic results.
This process is based on the Microsoft Windows XP environment.
Configuring Medical Objects Capricorn with The Practice
1. Double click the HL7 tray icon
Note: If the Capricorn HL7 tray icon is not visible, open Capricorn from the Start Menu > All Programs > Medical-Objects > Medical Objects Capricorn or from the C:\MO\Capricorn\Capricorn.exe.
2. The Log window is displayed
3. Click the Edit Server Properties icon
4. The Login screen will appear as shown below
5. Enter the following Username and Password and then click OK
Username: SYSDBA Password: masterkey
6. Click on the Integration Options
7. Set the ACK Management path to the local Import folder on the server or the network path on a workstation, that points to the server import folder
for example:
Acknowledgement paths in The Practice
(Capricorn installed on the Server) --> C:\ThePractice\PathRes\MoAcks
Or
(Capricorn installed on the Workstation) --> \\server\ThePractice\PathRes\MoAcks
NOTE: If the folders do not exist you must create them.
Integration Settings
Set Tick Box to "Convert to Pit"
Set Tick Box to "Preserve Sending Facility in Pit"
Set Incoming Modifier to "Capricorn Modifier"
9. Select Server Parameters from the left panel
10. Under the Message Output Directory (main) set the results import path
11. The path can be different depending on where Capricorn is installed for example:
Download paths in The Practice
(Capricorn installed on the Server) --> C:\ThePractice\PathRes\
Or
(Capricorn installed on the Workstation) --> \\server\ThePractice\PathRes\
12. The configuration is complete. Click Apply and OK
Should you require any more information or have encountered a problem please call the support helpdesk on (07) 5456 6000.