Configuring Medical-Objects Capricorn and Medical Director 2 and 3 to import electronic results
Version 1.0
Overview:
A procedure to provide the configuration that will enable importing of electronic results and the provision of acknowledgements.
Configuring Medical Objects Capricorn
1. Double click the HL7 tray icon
Note: If the Capricorn HL7 tray icon is not visible, open Capricorn from the Start Menu > All Programs > Medical-Objects > Medical Objects Capricorn or from the C:\MO\Capricorn\Capricorn.exe.
2. The Log window is displayed
3. Click the Edit Server Properties icon
4. The Login screen will appear as shown below
5. Enter the following Username and Password and then click OK
Username: SYSDBA Password: masterkey
6. Click on the Integration Options
7. Set the ACK Management path to the local Import folder on the server or the network path on a workstation, that points to the server import folder
for example:
Medical Director 2 (Capricorn installed on the Server) --> C:\MDW2\Out\Acks\ (Capricorn installed on the Workstation) --> \\server\MDW2\Out\Acks\
Medical Director 3 (Capricorn installed on the Server) --> C:\Program Files\Health Communication network\Messages\Out\Acks\ (Capricorn installed on the Workstation) --> \\Server\HCNMSGS\Out\Acks\
NOTE: If the folders do not exist you must create them.
8. Select Server Parameters from the left panel
9. Under the Message Output Directory (main) set the results import path
10. The path can be different depending on where Capricorn is installed for example:
Medical Director 2 (Capricorn installed on the Server) --> C:\MDW2\In\MO\ (Capricorn installed on the Workstation) --> \\server\MDW2\In\MO\
Medical Director 3 (Capricorn installed on the Server) --> C:\Program Files\Health Communication network\Messages\In\MO\ (Capricorn installed on the Workstation) --> \\Server\HCNMSGS\In\MO\
NOTE: If the folders do not exist you must create them.
11. The configuration is complete. Click Apply and OK
Configuring Medical Director Acknowledgements
1. Open Medical Director (MD) 2 or 3
2. Once Medical Director (MD) has opened select Tools then Options
3. The following window will appear
4. Select the Investigations Tab
5. Make sure the Generate ACK files is ticked
6. Select the Setup Data transfer button
7. The Setup Data Transfer window will appear, select the Advanced button shown below
8. The Advanced Data Transfer window will appear. Select the Add button shown below
9. Once you have clicked the Add button the Import/Export configuration window will appear
NOTE: The information in the screen has to be the same as shown above. The server name will be the only part that will generally change. The UNC path cannot be typed in, you must use the browse function to obtain the path shown below.
10. Once the Import/Export configuration is completed just click Save
11. Click Close on the Advanced Data Transfer window
12. Click Save on the Setup Data Transfer window
13. Click Save on the Options window
NOTE: The configuration is now complete for Medical Director.
Should you require any more information or have encountered a problem please call the support helpdesk on (07) 5456 6000.