Configuring Medical-Objects Capricorn and Medical Director 2 and 3 to import electronic results

From Medical-Objects Documentation Wiki
Jump to: navigation, search

MedicalObjects Banner.jpg

Version 1.0


Overview:

A procedure to provide the configuration that will enable importing of electronic results and the provision of acknowledgements.


Configuring Medical Objects Capricorn

1. Double click the HL7 tray icon


Cmd cmoc 1.jpg

Note: If the Capricorn HL7 tray icon is not visible, open Capricorn from the Start Menu > All Programs > Medical-Objects > Medical Objects Capricorn or from the C:\MO\Capricorn\Capricorn.exe.


2. The Log window is displayed


Cmd cmoc 2.jpg

3. Click the Edit Server Properties icon


Cmd cmoc 3.jpg

4. The Login screen will appear as shown below


Cmd cmoc 4.jpg

5. Enter the following Username and Password and then click OK


Username:	SYSDBA

Password:	masterkey

6. Click on the Integration Options


Cmoc 6 copy.png

7. Set the ACK Management path to the local Import folder on the server or the network path on a workstation, that points to the server import folder

for example:

Medical Director 2

(Capricorn installed on the Server) --> C:\MDW2\Out\Acks\

(Capricorn installed on the Workstation) --> \\server\MDW2\Out\Acks\
Medical Director 3

(Capricorn installed on the Server) --> C:\Program Files\Health Communication network\Messages\Out\Acks\

(Capricorn installed on the Workstation) --> \\Server\HCNMSGS\Out\Acks\


NOTE: If the folders do not exist you must create them.


8. Select Server Parameters from the left panel


Cmd cmoc 8.jpg

9. Under the Message Output Directory (main) set the results import path

10. The path can be different depending on where Capricorn is installed for example:


Medical Director 2

(Capricorn installed on the Server) --> C:\MDW2\In\MO\

(Capricorn installed on the Workstation) --> \\server\MDW2\In\MO\
Medical Director 3

(Capricorn installed on the Server) --> C:\Program Files\Health Communication network\Messages\In\MO\

(Capricorn installed on the Workstation) --> \\Server\HCNMSGS\In\MO\

NOTE: If the folders do not exist you must create them.


11. The configuration is complete. Click Apply and OK

Configuring Medical Director Acknowledgements

1. Open Medical Director (MD) 2 or 3


Cmd cmda 1.jpg

2. Once Medical Director (MD) has opened select Tools then Options


Cmd cmda 2.jpg

3. The following window will appear


4. Select the Investigations Tab


Cmd cmda 4.jpg

5. Make sure the Generate ACK files is ticked


6. Select the Setup Data transfer button


Cmd cmda 6.jpg

7. The Setup Data Transfer window will appear, select the Advanced button shown below


Cmd cmda 7.jpg

8. The Advanced Data Transfer window will appear. Select the Add button shown below


Cmd cmda 8.jpg

9. Once you have clicked the Add button the Import/Export configuration window will appear


Cmd cmda 9a.jpg

NOTE: The information in the screen has to be the same as shown above. The server name will be the only part that will generally change. The UNC path cannot be typed in, you must use the browse function to obtain the path shown below.


Cmd cmda 9b.jpg

10. Once the Import/Export configuration is completed just click Save


11. Click Close on the Advanced Data Transfer window


12. Click Save on the Setup Data Transfer window


13. Click Save on the Options window


NOTE: The configuration is now complete for Medical Director.