Configuring Medical-Objects Capricorn and Shexie to import electronic results

From Medical-Objects Documentation Wiki
Jump to: navigation, search

MedicalObjects Banner.jpg

Overview

Provide a procedure to install and configure Medical-Objects Capricorn and Shexie Practice software to import electronic results.

This process is based on the Microsoft Windows XP environment.

Note: Make sure you have the newest version of Shexie, this instruction uses Version 6.0 Revision 414


Version953.jpg


Configuring Medical Objects Capricorn with Shexie

1. Double click the HL7 tray icon


Cmd cmoc 1.jpg

Note: If the Capricorn HL7 tray icon is not visible, open Capricorn from the Start Menu > All Programs > Medical-Objects > Medical Objects Capricorn or from the C:\MO\Capricorn\Capricorn.exe.


2. The Log window is displayed


Cmd cmoc 2.jpg

3. Click the Edit Server Properties icon


Cmd cmoc 3.jpg

4. The Login screen will appear as shown below


Cmd cmoc 4.jpg

5. Enter the following Username and Password and then click OK


Username:	SYSDBA

Password:	masterkey

6. Click on the Integration Options


Intergration013.jpg


7. Set the ACK Management path to the local Import folder on the server or the network path on a workstation, that points to the server import folder

for example:

Acknowledgement paths in Shexie

(Capricorn installed on the Server) --> C:\Shexie\pathology\MoAcks

Or

(Capricorn installed on the Workstation) --> \\server\Shexie\pathology\MoAcks

NOTE: If the folders do not exist you must create them.


Integration Settings

Set Tick Box to "Evaluate and Strip"

Set Tick Box to "Convert to Pit"

Set Tick Box to "Preserve Sending Facility in Pit"

Set Incoming Modifier to "Capricorn Modifier"



9. Select Server Parameters from the left panel


Parameters205.jpg


10. Under the Message Output Directory (main) set the results import path


11. The path can be different depending on where Capricorn is installed for example:


Download paths in Shexie

(Capricorn installed on the Server) --> C:\Shexie\pathology\

Or

(Capricorn installed on the Workstation) --> \\server\Shexie\pathology\


12. The configuration is complete. Click Apply and OK


Shexie

(If performing the steps below doesn't show any of your reports, and they stay remaining in the folder - call Shexie(1300743943) as they will need to further configure Shexie to import)

1. To check Pathology results go to the Housekeeping Tab and then select Pathology


Path637.jpg


2. This will then display the Pathology Results you have received


Path303.jpg


3. To check if Specialist or Allied health letters have arrived select E-Letters


Letters415.jpg


4. This will then display the E-Letters you have received


Eletters155.jpg





Should you require any more information or have encountered a problem please call the support helpdesk on (07) 5456 6000.

Personal tools
Namespaces
Variants
Actions
Navigation
Software
Practice Software
Other
Toolbox